  Number of        
  steam Net capacity Replacement Tube Year of
Plant generators (MWe) supplier material replacement
Gravelines 4 3 910 FRA 1-690 TT 2000
Indian Point 2 4 864 W 1-600 TT 2000
Kewaunee 2 540 W 1-690 TT 2000
Arkansas Nuclear One – Unit 2 2 858 W 1-690 TT 2000
Shearon Harris 2 900 W 1-690 TT 2001
Joseph M Farley 2 3 829 W 1-690 TT 2001
Tihange 2 3 942 MHI 1-690 TT 2001
Tricastin 3 3 915 FRA 1-690 TT 2001
Calvert Cliffs 1 2 911 BWI 1-690 TT 2002
Fessenheim 1 3 900 FRA 1-690 TT 2002
South Texas 2 4 1250 W 1-690 TT 2002
Calvert Cliffs 2 2 911 BWI 1-690 TT 2003
Palo Verde 2 2 1270 ABB CE 1-690 TT 2003
Tricastin 4 3 915 FRA 1-690 TT 2003
St Laurent B2 3 880 FRA 1-690 TT 2003
Oconee 1 2 846 BWI 1-690 TT 2003
Oconee 2 2 846 BWI 1-690 TT 2004
Sequoyah 1 4 1148 HAN 1-690 TT 2004
Oconee 3 2 846 BWI 1-690 TT 2005
Prairie Island 1 2 203 FRA 1-690 TT 2005
Callaway 4 1240     2005
ABB CE = ABB Combustion/Engineering HAN = Hanjung/BWI = B&W International/MHI = Mitsubishi Heavy Industries/FRA = Framatome ANP/W = Westinghouse