Test results of the DN 400 regulating disc valve at SG 1 of Rovno 3

1 January 2000


Test results of the DN 400 regulating disc valve at SG 1 of Rovno 3
Description New valve Old valve
Valve type Disc Slide
Diameter (conventional), mm 400 400
Nominal flow, t/h 1520 1520
Maximum permitted pressure differential, MPa 9.0 2.0
Drive power, kW 0.18 3.2/5.6
Speed of response, s 25 56/38
Real flow, t/h 1420 1420
Flow fluctuation, t/h up to 35 up to 40
Valve vibration, mm/s 5.0 5.7
Degree of openess (%) 72 75
Nominal pressure differential, MPa 0.70 0.70
Uncontrolled flow and leak at p = 2.3MPa (% nominal flow) 0.07 up to 4
SG level deviation in nominal mode ±12mm ±18mm
SG level deviation at main primary coolant pump #3 trip -90mm -150mm
Flow characteristic Close to linear Close to linear
Throughput (t/h) 810 645



Privacy Policy
We have updated our privacy policy. In the latest update it explains what cookies are and how we use them on our site. To learn more about cookies and their benefits, please view our privacy policy. Please be aware that parts of this site will not function correctly if you disable cookies. By continuing to use this site, you consent to our use of cookies in accordance with our privacy policy unless you have disabled them.