Table 1

1 January 2000


Table 1: IGSCC sizing by different ultrasonic techniques* Known depth, used for reference
Sr. No. Depth of IGSCC measured by metallography (mm) Depth of IGSCC estimated using 10% deep notch standard (mm) Depth of IGSCC using known depth IGSCC as reference standard (mm) Depth of IGSCC estimated using tip diffraction technique (mm)
1 7.7 2.4 7.7* 7.7
2 6.7 2.1 4.8 6.6
3 7 1.5 3 7
4 4.3 1.9 3.2 4.9
5 5.8 1.2 2.4 5.6



Privacy Policy
We have updated our privacy policy. In the latest update it explains what cookies are and how we use them on our site. To learn more about cookies and their benefits, please view our privacy policy. Please be aware that parts of this site will not function correctly if you disable cookies. By continuing to use this site, you consent to our use of cookies in accordance with our privacy policy unless you have disabled them.